50 Amp Terrapin Station II™, Feed Thru Spider Box to GFCI Duplex/L6-30 Receptacles

T2-A2-6A1E T2-A2-6A1E

50 Amp Terrapin Station II™, Feed Thru Spider Box to GFCI Duplex/L6-30 Receptacles

50A 125/250 VAC, (1) California Style CS63 Male (Inlet) to (6) NEMA 5-20 (Edison) Receptacles and (1) NEMA L6-30 Receptacle, Feed Thru, Terrapin Station

Part Number T2-A2-6A1E
Markets Entertainment  Industrial 
Rating Outdoor 
Enclosure Box
Input California Style 
Output NEMA 
Amperage 50A
Certifications Certification Icon
Data Sheet Print

Features & Benefits

-Meets UL, NEC and OSHA requirements for events and generator rental
-Meets OSHA Regulation 20 Part 1926, Subpart K standards for open-neutral GFCI protection for enhanced safety
-Heavy duty molded rubber enclosure is fully insulated and resistant to shock, impact and corrosion for years of trouble-free service versus painted metal
-Thermal magnetic circuit breakers are located under a heavy duty rubber, waterproof, self-closing lid for enhanced breaker protection
-Weather resistant GFCI protection helps to prevent unsafe operating conditions and nuisance tripping
-GFCI module possesses LED beacon to indicate device status
-Locking receptacles provide secure connections that prevent accidental separation
-cULus Listed and TYPE 3R Rainproof for outdoor use
-Feed thru feature allows multiple boxes to be placed along one feed
-Spring-loaded covers protect receptacles and inlets from dirt and moisture intrusion
-Lightweight and compact for easy portability and storage
-Heavy-duty aluminum legs position the box at the NEC regulatory height of 6 inches while allowing for storage and transport stacking
-Molded handle enhances portability while improving stack ability of multiple units

Markets Served

Electrical Distribution, Maintenance, Shipbuilding, Generator Rental, Construction, Outdoor Events, Shelters

Technical Information

-Rating 50 Amp, Single Phase (H, H, N, G), 3 Pole, 4 Wire, 125/250 VAC
-Environmental Rating NEMA Type 3R (Weather Resistant)
-Input (1) 50 Amp, 3-Pole, 4-Wire, 125/250 VAC, California-style locking receptacles
-Output (6) NEMA 5-20, 20 Amp, 2 Pole, 3 Wire, 125 VAC, duplex receptacle, panel mount, GFCI open-neutral protected; (1) NEMA L6-30, 30 Amp, 2-Pole, 3-Wire, 250 VAC locking receptacle
-Feed Thru: Yes
-Overcurrent Protection (6) 20 Amp, 120 VAC, single pole, hydraulic magnetic, branch-rated circuit breakers, (1) 30 Amp, 250 VAC, double pole, hydraulic magnetic, branch-rated circuit breaker
-Enclosure Type: Terrapin Station
-Dimensions 14.25"L x 14.25"W x 17.50"H
-Weight 29.0 lbs.
-Agency Approval: cULus Listed